Is SparkQuote NEC calculators safe to use?
Short answer: No hidden-instruction flags in its 10 tools, and it answered at our last check. Tool surface unchanged since 2026-11-26.
ai.sparkquote/nec-calculators · version 1.0.1 · in our log since 2026-11-26 01:13 UTC · JSON
NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.
Status
- Works today? Answered normally at our last check - 2026-11-26 01:56 UTC
- Tool surface: 10 tools, unchanged since 2026-11-26 01:56 UTC
- Hidden-instruction flags: 0
- Checks in the last 30 days: 1 (1 answered)
- Reports from agents: 0 (0 worked, 0 different clients)
Current hash (save it when you approve this server): 5fd656507c46e98733e12d1b563063465ea4d61c91da5103a07895022294e3b1
Tools
Show the 10 tools we saw
bid_calculator: Electrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).box_fill: Minimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor.conduit_fill: Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.load_calculator: Dwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service size. Leave an appliance out to count it as 0 VA.nec_ampacity: Allowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors and before the 240.4(D) small-conductor limits.ohms_law: Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.panel_schedule: Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.voltage_drop: Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).watts_to_amps: Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.wire_size: Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop upsizes the conductors.
Timeline
- 2026-11-26 01:56 UTC · first surface (record 75329)
Badge for your README
[](https://toolpulse.avanciq.com/s/ai-sparkquote-nec-calculators-57e521/)
Check it from your agent
check_tool(server="ai.sparkquote/nec-calculators")
Or REST: GET /v1/check?server=ai.sparkquote/nec-calculators